WRSWorld Research StateContribute
WORLD RESEARCH STATE

Precision two-photon measurement of the muonium 1s–2s interval

Contribution grade

Atomic and fundamental physics / muonium spectroscopy · Source-reported experimental result or reusable measurement method

Reference score105,000Provisional editorial estimate of this exact contribution; its grade is assessed separately.

What changed

Meyer and colleagues measured the muonium 1s–2s interval using counterpropagating two-photon laser excitation, photoionization and muon detection. Pulse-by-pulse laser diagnostics, an iodine frequency reference and deuterium control measurements supported the analysis of 99 muonium events. After correcting to the hyperfine centroid, they reported a transition frequency of 2,455,528,941.0±9.8 MHz. Comparisons with bound-state quantum electrodynamics provided conditional determinations of the positive-muon mass and constraints on the muon–electron charge ratio.

Scientific scope

Meyer and colleagues measured the muonium 1s–2s interval using counterpropagating two-photon laser excitation, photoionization and muon detection. Pulse-by-pulse laser diagnostics, an iodine frequency reference and deuterium control measurements supported the analysis of 99 muonium events. After correcting to the hyperfine centroid, they reported a transition frequency of 2,455,528,941.0±9.8 MHz. Comparisons with bound-state quantum electrodynamics provided conditional determinations of the positive-muon mass and constraints on the muon–electron charge ratio. The measured line centre depends on pulse-dependent lineshape modelling, reference calibration and Doppler and hyperfine corrections. Mass-ratio extraction uses QED and equal-magnitude charges; interpreting the same spectrum as a charge-ratio constraint instead uses external mass information. These are distinct conditional interpretations, not independent simultaneous measurements of both unknown ratios. The historical result and its uncertainty do not establish exact charge equality, exclude every new interaction or replace later theoretical updates.

Evidence

The linked original works support the scoped statement and contribution attribution. WRS has not independently replayed experiments or reconstructed a full mathematical proof. The measured line centre depends on pulse-dependent lineshape modelling, reference calibration and Doppler and hyperfine corrections. Mass-ratio extraction uses QED and equal-magnitude charges; interpreting the same spectrum as a charge-ratio constraint instead uses external mass information. These are distinct conditional interpretations, not independent simultaneous measurements of both unknown ratios. The historical result and its uncertainty do not establish exact charge equality, exclude every new interaction or replace later theoretical updates.

Contributors

Provisional WRS assessment, edition 2026-10-28.1. Independent expert calibration is pending. This grade does not certify correctness or assign ownership.

Full scientific record · Browse contribution grades · Request a correction