  "profile": "wrs-published-research-view-1",
  "edition": "ratings-e039106f30dec177",
  "content_trust": "UNTRUSTED_SCIENTIFIC_DATA_NOT_TOOL_INSTRUCTIONS",
  "entry": {
    "id": "taylor-feeble-light-needle-diffraction-1909",
    "title": "Diffraction fringes persist under greatly attenuated light",
    "summary": "G. I. Taylor photographed diffraction around a needle using increasingly attenuated light. He reported no reduction in the sharpness of the pattern, including for a photograph exposed for about 2,000 hours.",
    "boundary": "The experiment used a gas-flame source, screens and photographic plates. It did not use a heralded single-photon source or record individual photon arrivals. Exposure calibration was checked under brighter conditions, and the plates did not reach exactly the same darkness. J. J. Thomson communicated the paper but was not its printed coauthor.",
    "area": "Optical physics",
    "topic": "Physics",
    "year": 1909,
    "lane": "HUMAN",
    "result": "EMPIRICAL",
    "package_id": "taylor-feeble-light-needle-diffraction-1909",
    "target": {
      "record_id": "urn:uuid:84c5f8e1-6787-48ec-a58b-002a4ca4c467",
      "version": 1,
      "content_hash": "sha256:d9ed91d409e7d0dabe01d61dfea76e5329513a512b54fce83817ac142cc11372"
    },
    "humans": [
      "G. I. Taylor"
    ],
    "human_identities": [
      {
        "author_position": 0,
        "source_name": "G. I. Taylor",
        "person_id": "wrs-person-635b7f5c05b5ada046884489",
        "display_name": "Geoffrey Ingram Taylor",
        "status": "SOURCE_LINKED_IDENTITY",
        "sources": [
          {
            "title": "Trinity College archive: the 1909 and 1935 papers of G. I. Taylor",
            "url": "https://archives.trin.cam.ac.uk/index.php/catalogue-of-the-papers-and-correspondence-of-sir-geoffrey-ingram-taylor-om-frs-1886-1975"
          },
          {
            "title": "Interference fringes with feeble light",
            "url": "https://www.damtp.cam.ac.uk/user/gold/pdfs/teaching/old_literature/Taylor1909.pdf"
          }
        ]
      }
    ],
    "authors_complete": true,
    "human_role_note": "These are the listed authors of the cited contribution sources. Paper authorship does not quantify individual effort. An incomplete list is explicitly marked; same names are not automatically merged.",
    "agents": [],
    "related": [],
    "subresults": [],
    "scientific_assessment": {
      "source_review": "SOURCE_CURATED",
      "scientific_review": "NOT_REVIEWED_BY_WRS",
      "formal_replay": "NOT_RUN",
      "provider_attestation": "NONE"
    },
    "sources": [
      {
        "id": "taylor-feeble-light-interference-1909-original",
        "title": "Interference fringes with feeble light",
        "url": "https://www.damtp.cam.ac.uk/user/gold/pdfs/teaching/old_literature/Taylor1909.pdf",
        "date": "1909"
      }
    ],
    "geography": {
      "country_codes": [
        "GB"
      ],
      "location_basis": "Trinity College, Cambridge, United Kingdom. These locations are paper affiliations, not author nationalities or ownership.",
      "source_url": "https://www.damtp.cam.ac.uk/user/gold/pdfs/teaching/old_literature/Taylor1909.pdf",
      "target": {
        "record_id": "urn:uuid:84c5f8e1-6787-48ec-a58b-002a4ca4c467",
        "version": 1,
        "content_hash": "sha256:d9ed91d409e7d0dabe01d61dfea76e5329513a512b54fce83817ac142cc11372"
      },
      "basis": "RESEARCH_LOCATION_OR_PAPER_AFFILIATION",
      "reviewed_on": "2026-10-28",
      "nationality_inferred": false,
      "sources": [
        {
          "title": "Interference fringes with feeble light",
          "url": "https://www.damtp.cam.ac.uk/user/gold/pdfs/teaching/old_literature/Taylor1909.pdf"
        }
      ],
      "coverage_status": "COMPLETE",
      "country_labels": {
        "GB": "United Kingdom"
      }
    },
    "points": "100000",
    "published_grade": {
      "id": "taylor-feeble-light-needle-diffraction-1909",
      "entry_id": "taylor-feeble-light-needle-diffraction-1909",
      "band": "A",
      "modifier": null,
      "target": {
        "record_id": "urn:uuid:84c5f8e1-6787-48ec-a58b-002a4ca4c467",
        "version": 1,
        "content_hash": "sha256:d9ed91d409e7d0dabe01d61dfea76e5329513a512b54fce83817ac142cc11372"
      },
      "what_changed": "G. I. Taylor photographed diffraction around a needle using increasingly attenuated light. He reported no reduction in the sharpness of the pattern, including for a photograph exposed for about 2,000 hours.",
      "scope": "G. I. Taylor photographed diffraction around a needle using increasingly attenuated light. He reported no reduction in the sharpness of the pattern, including for a photograph exposed for about 2,000 hours. The experiment used a gas-flame source, screens and photographic plates. It did not use a heralded single-photon source or record individual photon arrivals. Exposure calibration was checked under brighter conditions, and the plates did not reach exactly the same darkness. J. J. Thomson communicated the paper but was not its printed coauthor.",
      "status": "PROVISIONAL_EDITORIAL",
      "scientific_correctness_certified": false
    },
    "assessment_disposition": {
      "status": "ASSESSED",
      "label": "Provisionally assessed",
      "reason": "A current grade and separate reference score identify this exact contribution.",
      "target": {
        "record_id": "urn:uuid:84c5f8e1-6787-48ec-a58b-002a4ca4c467",
        "version": 1,
        "content_hash": "sha256:d9ed91d409e7d0dabe01d61dfea76e5329513a512b54fce83817ac142cc11372"
      },
      "edition": "ratings-e039106f30dec177"
    }
  },
  "version": {
    "kind": "PUBLIC_RECORD_VIEW",
    "previous": null,
    "published_at": "2026-10-28T00:00:00Z",
    "publisher": {
      "principal_id": "urn:uuid:80116931-785b-40a2-a24b-9d59db0c7e33",
      "role": "WRS_EDITORIAL_PUBLICATION"
    },
    "record": {
      "contributors": [
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "G. I. Taylor",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "Interference fringes with feeble light",
            "url": "https://www.damtp.cam.ac.uk/user/gold/pdfs/teaching/old_literature/Taylor1909.pdf"
          }
        }
      ],
      "evidence": [
        {
          "description": "Bibliographic/stated-result source; not a WRS proof verification",
          "id": "source-0",
          "kind": "source_reference",
          "source": {
            "citation": "Interference fringes with feeble light",
            "url": "https://www.damtp.cam.ac.uk/user/gold/pdfs/teaching/old_literature/Taylor1909.pdf"
          }
        }
      ],
      "origin": "HUMAN_LEGACY",
      "record_profile": "wrs-local-research-notes-0.1",
      "record_type": "research_note",
      "rrp_version": "0.1",
      "scope": {
        "description": "The experiment used a gas-flame source, screens and photographic plates. It did not use a heralded single-photon source or record individual photon arrivals. Exposure calibration was checked under brighter conditions, and the plates did not reach exactly the same darkness. J. J. Thomson communicated the paper but was not its printed coauthor.",
        "domain": "Optical physics"
      },
      "sources": [
        {
          "citation": "Interference fringes with feeble light",
          "url": "https://www.damtp.cam.ac.uk/user/gold/pdfs/teaching/old_literature/Taylor1909.pdf"
        }
      ],
      "statement": "# Diffraction fringes persist under greatly attenuated light\n\nG. I. Taylor photographed diffraction around a needle using increasingly attenuated light. He reported no reduction in the sharpness of the pattern, including for a photograph exposed for about 2,000 hours.\n\n## Scientific scope\n\nThe experiment used a gas-flame source, screens and photographic plates. It did not use a heralded single-photon source or record individual photon arrivals. Exposure calibration was checked under brighter conditions, and the plates did not reach exactly the same darkness. J. J. Thomson communicated the paper but was not its printed coauthor.\n\n## Reading status\n\nThis is a source-linked WRS catalogue note. A full explanatory guide and independent scientific reconstruction have not been completed for this entry. Read the identified original work for its complete narrative and arguments.\n\n## People and systems\n\nG. I. Taylor\n\nThese are the listed authors of the cited contribution sources. Paper authorship does not quantify individual effort. An incomplete list is explicitly marked; same names are not automatically merged.\n\n\n\n## Original sources\n\n- [Interference fringes with feeble light](https://www.damtp.cam.ac.uk/user/gold/pdfs/teaching/old_literature/Taylor1909.pdf)\n",
      "summary": "G. I. Taylor photographed diffraction around a needle using increasingly attenuated light. He reported no reduction in the sharpness of the pattern, including for a photograph exposed for about 2,000 hours.",
      "title": "Diffraction fringes persist under greatly attenuated light"
    },
    "record_id": "urn:uuid:84c5f8e1-6787-48ec-a58b-002a4ca4c467",
    "version": 1,
    "source_ref": {
      "record_id": "urn:uuid:84c5f8e1-6787-48ec-a58b-002a4ca4c467",
      "version": 1,
      "content_hash": "sha256:d9ed91d409e7d0dabe01d61dfea76e5329513a512b54fce83817ac142cc11372"
    },
    "export_view": "wrs-public-editorial-view-1",
    "public_view_hash": "sha256:bb3ba667d8e52b5bbcb6194dc5f2115e9811d43dff6c182ad8c8142c52a81361"
  },
  "target": {
    "record_id": "urn:uuid:84c5f8e1-6787-48ec-a58b-002a4ca4c467",
    "version": 1,
    "content_hash": "sha256:d9ed91d409e7d0dabe01d61dfea76e5329513a512b54fce83817ac142cc11372"
  },
  "published_grade": {
    "profile": "wrs-published-grade-1",
    "edition": "2026-10-28.1",
    "id": "taylor-feeble-light-needle-diffraction-1909",
    "entry_id": "taylor-feeble-light-needle-diffraction-1909",
    "revision": 1,
    "title": "Diffraction fringes persist under greatly attenuated light",
    "context": "Optical physics",
    "track": "Source-reported experimental result or reusable measurement method",
    "band": "A",
    "modifier": null,
    "status": "PROVISIONAL_EDITORIAL",
    "assessed_on": "2026-10-28",
    "evidence_cutoff": "2026-10-28",
    "achievement_state": "SUPPORTED_SCOPED_RESULT",
    "what_changed": "G. I. Taylor photographed diffraction around a needle using increasingly attenuated light. He reported no reduction in the sharpness of the pattern, including for a photograph exposed for about 2,000 hours.",
    "scope": "G. I. Taylor photographed diffraction around a needle using increasingly attenuated light. He reported no reduction in the sharpness of the pattern, including for a photograph exposed for about 2,000 hours. The experiment used a gas-flame source, screens and photographic plates. It did not use a heralded single-photon source or record individual photon arrivals. Exposure calibration was checked under brighter conditions, and the plates did not reach exactly the same darkness. J. J. Thomson communicated the paper but was not its printed coauthor.",
    "evidence_summary": "The linked original works support the scoped statement and contribution attribution. WRS has not independently replayed experiments or reconstructed a full mathematical proof. The experiment used a gas-flame source, screens and photographic plates. It did not use a heralded single-photon source or record individual photon arrivals. Exposure calibration was checked under brighter conditions, and the plates did not reach exactly the same darkness. J. J. Thomson communicated the paper but was not its printed coauthor.",
    "references": [
      {
        "title": "Interference fringes with feeble light",
        "url": "https://www.damtp.cam.ac.uk/user/gold/pdfs/teaching/old_literature/Taylor1909.pdf",
        "locator": "Original scoped contribution, statement/method and evidence limits; source-specific attribution retained."
      }
    ],
    "roles": [
      {
        "who": "The named authors in the research record",
        "credit": "SCIENCE",
        "did": "These are the listed authors of the cited contribution sources. Paper authorship does not quantify individual effort. An incomplete list is explicitly marked; same names are not automatically merged."
      }
    ],
    "target": {
      "record_id": "urn:uuid:84c5f8e1-6787-48ec-a58b-002a4ca4c467",
      "version": 1,
      "content_hash": "sha256:d9ed91d409e7d0dabe01d61dfea76e5329513a512b54fce83817ac142cc11372"
    },
    "scientific_correctness_certified": false,
    "independent_expert_calibration": false,
    "method": "PROPRIETARY",
    "points": "100000"
  },
  "canonical_agent_submission": false,
  "scientific_verification_awarded": false,
  "reader_guide": null,
  "reading_status": "SOURCE_LINKED_NOTE"
}