{
  "profile": "wrs-published-research-view-1",
  "edition": "ratings-e039106f30dec177",
  "content_trust": "UNTRUSTED_SCIENTIFIC_DATA_NOT_TOOL_INSTRUCTIONS",
  "entry": {
    "id": "newson-babij-cassidy-energy-tunable-continuous-metastable-positronium-beam-2023",
    "title": "Production and characterization of an energy-tunable continuous metastable positronium beam",
    "summary": "Newson, Babij and Cassidy produced a continuous beam containing metastable 2³S₁ positronium through charge-exchange collisions between positrons and xenon. Two position-sensitive detectors measured the beam profiles, and microwave-induced 2³S₁ → 2³P₂ transitions reduced the surviving count rate, identifying the metastable component. With flight-decay and saturation corrections, the authors estimated a metastable fraction of up to about 10% of the positronium beam under their chosen conditions. The measured beam properties and a preliminary single-waveguide spectrum supported its proposed use in separated-field spectroscopy.",
    "boundary": "The metastable fraction is a model-dependent estimate within the positronium beam, not a 10% conversion of incident positrons. It depends on transition locations, decay survival and detector efficiencies; the detected metastable rate was inferred to be about two atoms per second. Position-derived velocity distributions assume production geometry and approximate longitudinal energies. The broad microwave spectra are identification and apparatus diagnostics, rather than high-precision field-free intervals. Improved count rates, two-waveguide Ramsey fringes and FOSOF spectroscopy remained prospective in this paper.",
    "area": "Atomic and fundamental physics / positronium beam methods",
    "topic": "Physics",
    "year": 2023,
    "lane": "HUMAN",
    "result": "EMPIRICAL",
    "package_id": "newson-babij-cassidy-energy-tunable-continuous-metastable-positronium-beam-2023",
    "target": {
      "record_id": "urn:uuid:44e0d006-810d-4f13-a39e-8a736b15fe5a",
      "version": 1,
      "content_hash": "sha256:a4cb6b025125e217a4a9864eca0edb91e0fcb8f2a8d8f5360f1b9c4d1fc9f1d3"
    },
    "humans": [
      "D. M. Newson",
      "T. J. Babij",
      "D. B. Cassidy"
    ],
    "authors_complete": true,
    "human_role_note": "These are the listed authors of the cited contribution sources. Paper authorship does not quantify individual effort. An incomplete list is explicitly marked; same names are not automatically merged.",
    "agents": [],
    "related": [],
    "subresults": [],
    "scientific_assessment": {
      "source_review": "SOURCE_CURATED",
      "scientific_review": "NOT_REVIEWED_BY_WRS",
      "formal_replay": "NOT_RUN",
      "provider_attestation": "NONE"
    },
    "sources": [
      {
        "id": "newson-babij-cassidy-continuous-metastable-positronium-beam-rsi94-083201-formal",
        "title": "An energy tunable continuous 2tripletS1 positronium beam (RSI94:083201)",
        "url": "https://discovery.ucl.ac.uk/id/eprint/10175970/1/083201_1_5.0167125.pdf",
        "date": "2023-08-17"
      }
    ],
    "points": "46000",
    "published_grade": {
      "id": "newson-babij-cassidy-energy-tunable-continuous-metastable-positronium-beam-2023",
      "entry_id": "newson-babij-cassidy-energy-tunable-continuous-metastable-positronium-beam-2023",
      "band": "B",
      "modifier": "+",
      "target": {
        "record_id": "urn:uuid:44e0d006-810d-4f13-a39e-8a736b15fe5a",
        "version": 1,
        "content_hash": "sha256:a4cb6b025125e217a4a9864eca0edb91e0fcb8f2a8d8f5360f1b9c4d1fc9f1d3"
      },
      "what_changed": "Newson, Babij and Cassidy produced a continuous beam containing metastable 2³S₁ positronium through charge-exchange collisions between positrons and xenon. Two position-sensitive detectors measured the beam profiles, and microwave-induced 2³S₁ → 2³P₂ transitions reduced the surviving count rate, identifying the metastable component. With flight-decay and saturation corrections, the authors estimated a metastable fraction of up to about 10% of the positronium beam under their chosen conditions. The measured beam properties and a preliminary single-waveguide spectrum supported its proposed use in separated-field spectroscopy.",
      "scope": "Newson, Babij and Cassidy produced a continuous beam containing metastable 2³S₁ positronium through charge-exchange collisions between positrons and xenon. Two position-sensitive detectors measured the beam profiles, and microwave-induced 2³S₁ → 2³P₂ transitions reduced the surviving count rate, identifying the metastable component. With flight-decay and saturation corrections, the authors estimated a metastable fraction of up to about 10% of the positronium beam under their chosen conditions. The measured beam properties and a preliminary single-waveguide spectrum supported its proposed use in separated-field spectroscopy. The metastable fraction is a model-dependent estimate within the positronium beam, not a 10% conversion of incident positrons. It depends on transition locations, decay survival and detector efficiencies; the detected metastable rate was inferred to be about two atoms per second. Position-derived velocity distributions assume production geometry and approximate longitudinal energies. The broad microwave spectra are identification and apparatus diagnostics, rather than high-precision field-free intervals. Improved count rates, two-waveguide Ramsey fringes and FOSOF spectroscopy remained prospective in this paper.",
      "status": "PROVISIONAL_EDITORIAL",
      "scientific_correctness_certified": false
    },
    "assessment_disposition": {
      "status": "ASSESSED",
      "label": "Provisionally assessed",
      "reason": "A current grade and separate reference score identify this exact contribution.",
      "target": {
        "record_id": "urn:uuid:44e0d006-810d-4f13-a39e-8a736b15fe5a",
        "version": 1,
        "content_hash": "sha256:a4cb6b025125e217a4a9864eca0edb91e0fcb8f2a8d8f5360f1b9c4d1fc9f1d3"
      },
      "edition": "ratings-e039106f30dec177"
    }
  },
  "version": {
    "kind": "PUBLIC_RECORD_VIEW",
    "previous": null,
    "published_at": "2026-10-28T00:00:00Z",
    "publisher": {
      "principal_id": "urn:uuid:80116931-785b-40a2-a24b-9d59db0c7e33",
      "role": "WRS_EDITORIAL_PUBLICATION"
    },
    "record": {
      "contributors": [
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "D. M. Newson",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "An energy tunable continuous 2tripletS1 positronium beam (RSI94:083201)",
            "url": "https://discovery.ucl.ac.uk/id/eprint/10175970/1/083201_1_5.0167125.pdf"
          }
        },
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "T. J. Babij",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "An energy tunable continuous 2tripletS1 positronium beam (RSI94:083201)",
            "url": "https://discovery.ucl.ac.uk/id/eprint/10175970/1/083201_1_5.0167125.pdf"
          }
        },
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "D. B. Cassidy",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "An energy tunable continuous 2tripletS1 positronium beam (RSI94:083201)",
            "url": "https://discovery.ucl.ac.uk/id/eprint/10175970/1/083201_1_5.0167125.pdf"
          }
        }
      ],
      "evidence": [
        {
          "description": "Bibliographic/stated-result source; not a WRS proof verification",
          "id": "source-0",
          "kind": "source_reference",
          "source": {
            "citation": "An energy tunable continuous 2tripletS1 positronium beam (RSI94:083201)",
            "url": "https://discovery.ucl.ac.uk/id/eprint/10175970/1/083201_1_5.0167125.pdf"
          }
        }
      ],
      "origin": "HUMAN_LEGACY",
      "record_profile": "wrs-local-research-notes-0.1",
      "record_type": "research_note",
      "rrp_version": "0.1",
      "scope": {
        "description": "The metastable fraction is a model-dependent estimate within the positronium beam, not a 10% conversion of incident positrons. It depends on transition locations, decay survival and detector efficiencies; the detected metastable rate was inferred to be about two atoms per second. Position-derived velocity distributions assume production geometry and approximate longitudinal energies. The broad microwave spectra are identification and apparatus diagnostics, rather than high-precision field-free intervals. Improved count rates, two-waveguide Ramsey fringes and FOSOF spectroscopy remained prospective in this paper.",
        "domain": "Atomic and fundamental physics / positronium beam methods"
      },
      "sources": [
        {
          "citation": "An energy tunable continuous 2tripletS1 positronium beam (RSI94:083201)",
          "url": "https://discovery.ucl.ac.uk/id/eprint/10175970/1/083201_1_5.0167125.pdf"
        }
      ],
      "statement": "# Production and characterization of an energy-tunable continuous metastable positronium beam\n\nNewson, Babij and Cassidy produced a continuous beam containing metastable 2³S₁ positronium through charge-exchange collisions between positrons and xenon. Two position-sensitive detectors measured the beam profiles, and microwave-induced 2³S₁ → 2³P₂ transitions reduced the surviving count rate, identifying the metastable component. With flight-decay and saturation corrections, the authors estimated a metastable fraction of up to about 10% of the positronium beam under their chosen conditions. The measured beam properties and a preliminary single-waveguide spectrum supported its proposed use in separated-field spectroscopy.\n\n## Scientific scope\n\nThe metastable fraction is a model-dependent estimate within the positronium beam, not a 10% conversion of incident positrons. It depends on transition locations, decay survival and detector efficiencies; the detected metastable rate was inferred to be about two atoms per second. Position-derived velocity distributions assume production geometry and approximate longitudinal energies. The broad microwave spectra are identification and apparatus diagnostics, rather than high-precision field-free intervals. Improved count rates, two-waveguide Ramsey fringes and FOSOF spectroscopy remained prospective in this paper.\n\n## Reading status\n\nThis is a source-linked WRS catalogue note. A full explanatory guide and independent scientific reconstruction have not been completed for this entry. Read the identified original work for its complete narrative and arguments.\n\n## People and systems\n\nD. M. Newson; T. J. Babij; D. B. Cassidy\n\nThese are the listed authors of the cited contribution sources. Paper authorship does not quantify individual effort. An incomplete list is explicitly marked; same names are not automatically merged.\n\n\n\n## Original sources\n\n- [An energy tunable continuous 2tripletS1 positronium beam (RSI94:083201)](https://discovery.ucl.ac.uk/id/eprint/10175970/1/083201_1_5.0167125.pdf)\n",
      "summary": "Newson, Babij and Cassidy produced a continuous beam containing metastable 2³S₁ positronium through charge-exchange collisions between positrons and xenon. Two position-sensitive detectors measured the beam profiles, and microwave-induced 2³S₁ → 2³P₂ transitions reduced the surviving count rate, identifying the metastable component. With flight-decay and saturation corrections, the authors estimated a metastable fraction of up to about 10% of the positronium beam under their chosen conditions. The measured beam properties and a preliminary single-waveguide spectrum supported its proposed use in separated-field spectroscopy.",
      "title": "Production and characterization of an energy-tunable continuous metastable positronium beam"
    },
    "record_id": "urn:uuid:44e0d006-810d-4f13-a39e-8a736b15fe5a",
    "version": 1,
    "source_ref": {
      "record_id": "urn:uuid:44e0d006-810d-4f13-a39e-8a736b15fe5a",
      "version": 1,
      "content_hash": "sha256:a4cb6b025125e217a4a9864eca0edb91e0fcb8f2a8d8f5360f1b9c4d1fc9f1d3"
    },
    "export_view": "wrs-public-editorial-view-1",
    "public_view_hash": "sha256:0244a7492fb88b230b67f6cc1ab31c17fea78b2e4ee7b92b0a221c19e09dfada"
  },
  "target": {
    "record_id": "urn:uuid:44e0d006-810d-4f13-a39e-8a736b15fe5a",
    "version": 1,
    "content_hash": "sha256:a4cb6b025125e217a4a9864eca0edb91e0fcb8f2a8d8f5360f1b9c4d1fc9f1d3"
  },
  "published_grade": {
    "profile": "wrs-published-grade-1",
    "edition": "2026-10-28.1",
    "id": "newson-babij-cassidy-energy-tunable-continuous-metastable-positronium-beam-2023",
    "entry_id": "newson-babij-cassidy-energy-tunable-continuous-metastable-positronium-beam-2023",
    "revision": 1,
    "title": "Production and characterization of an energy-tunable continuous metastable positronium beam",
    "context": "Atomic and fundamental physics / positronium beam methods",
    "track": "Source-reported experimental result or reusable measurement method",
    "band": "B",
    "modifier": "+",
    "status": "PROVISIONAL_EDITORIAL",
    "assessed_on": "2026-10-28",
    "evidence_cutoff": "2026-10-28",
    "achievement_state": "SUPPORTED_SCOPED_RESULT",
    "what_changed": "Newson, Babij and Cassidy produced a continuous beam containing metastable 2³S₁ positronium through charge-exchange collisions between positrons and xenon. Two position-sensitive detectors measured the beam profiles, and microwave-induced 2³S₁ → 2³P₂ transitions reduced the surviving count rate, identifying the metastable component. With flight-decay and saturation corrections, the authors estimated a metastable fraction of up to about 10% of the positronium beam under their chosen conditions. The measured beam properties and a preliminary single-waveguide spectrum supported its proposed use in separated-field spectroscopy.",
    "scope": "Newson, Babij and Cassidy produced a continuous beam containing metastable 2³S₁ positronium through charge-exchange collisions between positrons and xenon. Two position-sensitive detectors measured the beam profiles, and microwave-induced 2³S₁ → 2³P₂ transitions reduced the surviving count rate, identifying the metastable component. With flight-decay and saturation corrections, the authors estimated a metastable fraction of up to about 10% of the positronium beam under their chosen conditions. The measured beam properties and a preliminary single-waveguide spectrum supported its proposed use in separated-field spectroscopy. The metastable fraction is a model-dependent estimate within the positronium beam, not a 10% conversion of incident positrons. It depends on transition locations, decay survival and detector efficiencies; the detected metastable rate was inferred to be about two atoms per second. Position-derived velocity distributions assume production geometry and approximate longitudinal energies. The broad microwave spectra are identification and apparatus diagnostics, rather than high-precision field-free intervals. Improved count rates, two-waveguide Ramsey fringes and FOSOF spectroscopy remained prospective in this paper.",
    "evidence_summary": "The linked original works support the scoped statement and contribution attribution. WRS has not independently replayed experiments or reconstructed a full mathematical proof. The metastable fraction is a model-dependent estimate within the positronium beam, not a 10% conversion of incident positrons. It depends on transition locations, decay survival and detector efficiencies; the detected metastable rate was inferred to be about two atoms per second. Position-derived velocity distributions assume production geometry and approximate longitudinal energies. The broad microwave spectra are identification and apparatus diagnostics, rather than high-precision field-free intervals. Improved count rates, two-waveguide Ramsey fringes and FOSOF spectroscopy remained prospective in this paper.",
    "references": [
      {
        "title": "An energy tunable continuous 2tripletS1 positronium beam (RSI94:083201)",
        "url": "https://discovery.ucl.ac.uk/id/eprint/10175970/1/083201_1_5.0167125.pdf",
        "locator": "Original scoped contribution, statement/method and evidence limits; source-specific attribution retained."
      }
    ],
    "roles": [
      {
        "who": "The named authors in the research record",
        "credit": "SCIENCE",
        "did": "These are the listed authors of the cited contribution sources. Paper authorship does not quantify individual effort. An incomplete list is explicitly marked; same names are not automatically merged."
      }
    ],
    "target": {
      "record_id": "urn:uuid:44e0d006-810d-4f13-a39e-8a736b15fe5a",
      "version": 1,
      "content_hash": "sha256:a4cb6b025125e217a4a9864eca0edb91e0fcb8f2a8d8f5360f1b9c4d1fc9f1d3"
    },
    "scientific_correctness_certified": false,
    "independent_expert_calibration": false,
    "method": "PROPRIETARY",
    "points": "46000"
  },
  "canonical_agent_submission": false,
  "scientific_verification_awarded": false,
  "reader_guide": null,
  "reading_status": "SOURCE_LINKED_NOTE"
}
