  "profile": "wrs-published-research-view-1",
  "edition": "ratings-e039106f30dec177",
  "content_trust": "UNTRUSTED_SCIENTIFIC_DATA_NOT_TOOL_INSTRUCTIONS",
  "entry": {
    "id": "mumass-muonium-lamb-shift-and-isolated-hyperfine-spectroscopy-2021-2022",
    "title": "Muonium Lamb-shift and isolated excited-state hyperfine spectroscopy",
    "summary": "The Mu-MASS collaboration used a low-energy muon beam, carbon-foil muonium production and microwave-induced depletion of metastable atoms to measure the muonium n=2 Lamb shift. Ohayon and colleagues reported 1047.2±2.3(stat)±1.1(syst) MHz. Janka and colleagues then measured the isolated 2S1/2,F=0 to 2P1/2,F=1 transition at 580.6±6.8 MHz, deriving a Lamb shift of 1045.5±6.8 MHz and, together with the earlier transition measurement, a 2S hyperfine splitting of 559.6±7.2 MHz. The later line-shape analysis also identified a contribution from muonium in the n=3 excited state.",
    "boundary": "These are related measurements with simulated trajectory-dependent line shapes, microwave-power corrections and residual excited-state contamination. The isolated transition offers a route to lower systematic error, while its reported statistical uncertainty is larger than that of the earlier measurement. The excited-state population and combined hyperfine interval are inferred through the stated model and shared experimental inputs. Agreement with bound-state QED supports model-specific limits on additional interactions; it does not establish exact CPT symmetry or exclude every explanation of muon magnetic-moment measurements. A linked theoretical update reports a roughly 200 kHz disagreement between two predictions and explicitly leaves its origin unresolved; neither experiment resolves that difference at its stated precision.",
    "area": "Atomic and fundamental physics / leptonic-atom microwave spectroscopy",
    "topic": "Physics",
    "year": 2021,
    "lane": "HUMAN",
    "result": "EMPIRICAL",
    "package_id": "mumass-muonium-lamb-shift-and-isolated-hyperfine-spectroscopy-2021-2022",
    "target": {
      "record_id": "urn:uuid:840e173d-3312-4210-a3d6-51e993e746e2",
      "version": 1,
      "content_hash": "sha256:c0f9d26adfe45a38c6e6f66a4dd14adfbfb7d561ff3d836091c8c0df1ca6d8ea"
    },
    "humans": [
      "B. Ohayon",
      "G. Janka",
      "I. Cortinovis",
      "Z. Burkley",
      "L. de Sousa Borges",
      "E. Depero",
      "A. Golovizin",
      "X. Ni",
      "Z. Salman",
      "A. Suter",
      "C. Vigo",
      "T. Prokscha",
      "P. Crivelli"
    ],
    "authors_complete": true,
    "human_role_note": "These are the listed authors of the cited contribution sources. Paper authorship does not quantify individual effort. An incomplete list is explicitly marked; same names are not automatically merged.",
    "agents": [],
    "related": [],
    "subresults": [],
    "scientific_assessment": {
      "source_review": "SOURCE_CURATED",
      "scientific_review": "NOT_REVIEWED_BY_WRS",
      "formal_replay": "NOT_RUN",
      "provider_attestation": "NONE"
    },
    "sources": [
      {
        "id": "ohayon-mumass-muonium-lamb-shift-arxiv210812891v2",
        "title": "Precision measurement of the Lamb shift in Muonium (arXiv2108.12891v2)",
        "url": "https://arxiv.org/pdf/2108.12891v2",
        "date": "2021-08-29"
      },
      {
        "id": "janka-mumass-muonium-isolated-hyperfine-lamb-arxiv220506202v1",
        "title": "Measurement of the 2S1/2,F=0 to 2P1/2,F=1 transition in Muonium (arXiv2205.06202v1)",
        "url": "https://arxiv.org/pdf/2205.06202v1",
        "date": "2022-05-12"
      },
      {
        "id": "janka-ohayon-crivelli-muonium-lamb-theory-update-arxiv211113951v1",
        "title": "Muonium Lamb shift: theory update and experimental prospects (arXiv2111.13951v1)",
        "url": "https://arxiv.org/pdf/2111.13951v1",
        "date": "2021-11-27"
      }
    ],
    "points": "58000",
    "published_grade": {
      "id": "mumass-muonium-lamb-shift-and-isolated-hyperfine-spectroscopy-2021-2022",
      "entry_id": "mumass-muonium-lamb-shift-and-isolated-hyperfine-spectroscopy-2021-2022",
      "band": "B",
      "modifier": "+",
      "target": {
        "record_id": "urn:uuid:840e173d-3312-4210-a3d6-51e993e746e2",
        "version": 1,
        "content_hash": "sha256:c0f9d26adfe45a38c6e6f66a4dd14adfbfb7d561ff3d836091c8c0df1ca6d8ea"
      },
      "what_changed": "The Mu-MASS collaboration used a low-energy muon beam, carbon-foil muonium production and microwave-induced depletion of metastable atoms to measure the muonium n=2 Lamb shift. Ohayon and colleagues reported 1047.2±2.3(stat)±1.1(syst) MHz. Janka and colleagues then measured the isolated 2S1/2,F=0 to 2P1/2,F=1 transition at 580.6±6.8 MHz, deriving a Lamb shift of 1045.5±6.8 MHz and, together with the earlier transition measurement, a 2S hyperfine splitting of 559.6±7.2 MHz. The later line-shape analysis also identified a contribution from muonium in the n=3 excited state.",
      "scope": "The Mu-MASS collaboration used a low-energy muon beam, carbon-foil muonium production and microwave-induced depletion of metastable atoms to measure the muonium n=2 Lamb shift. Ohayon and colleagues reported 1047.2±2.3(stat)±1.1(syst) MHz. Janka and colleagues then measured the isolated 2S1/2,F=0 to 2P1/2,F=1 transition at 580.6±6.8 MHz, deriving a Lamb shift of 1045.5±6.8 MHz and, together with the earlier transition measurement, a 2S hyperfine splitting of 559.6±7.2 MHz. The later line-shape analysis also identified a contribution from muonium in the n=3 excited state. These are related measurements with simulated trajectory-dependent line shapes, microwave-power corrections and residual excited-state contamination. The isolated transition offers a route to lower systematic error, while its reported statistical uncertainty is larger than that of the earlier measurement. The excited-state population and combined hyperfine interval are inferred through the stated model and shared experimental inputs. Agreement with bound-state QED supports model-specific limits on additional interactions; it does not establish exact CPT symmetry or exclude every explanation of muon magnetic-moment measurements. A linked theoretical update reports a roughly 200 kHz disagreement between two predictions and explicitly leaves its origin unresolved; neither experiment resolves that difference at its stated precision.",
      "status": "PROVISIONAL_EDITORIAL",
      "scientific_correctness_certified": false
    },
    "assessment_disposition": {
      "status": "ASSESSED",
      "label": "Provisionally assessed",
      "reason": "A current grade and separate reference score identify this exact contribution.",
      "target": {
        "record_id": "urn:uuid:840e173d-3312-4210-a3d6-51e993e746e2",
        "version": 1,
        "content_hash": "sha256:c0f9d26adfe45a38c6e6f66a4dd14adfbfb7d561ff3d836091c8c0df1ca6d8ea"
      },
      "edition": "ratings-e039106f30dec177"
    }
  },
  "version": {
    "kind": "PUBLIC_RECORD_VIEW",
    "previous": null,
    "published_at": "2026-10-28T00:00:00Z",
    "publisher": {
      "principal_id": "urn:uuid:80116931-785b-40a2-a24b-9d59db0c7e33",
      "role": "WRS_EDITORIAL_PUBLICATION"
    },
    "record": {
      "contributors": [
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "B. Ohayon",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "Precision measurement of the Lamb shift in Muonium (arXiv2108.12891v2)",
            "url": "https://arxiv.org/pdf/2108.12891v2"
          }
        },
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "G. Janka",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "Precision measurement of the Lamb shift in Muonium (arXiv2108.12891v2)",
            "url": "https://arxiv.org/pdf/2108.12891v2"
          }
        },
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "I. Cortinovis",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "Precision measurement of the Lamb shift in Muonium (arXiv2108.12891v2)",
            "url": "https://arxiv.org/pdf/2108.12891v2"
          }
        },
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "Z. Burkley",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "Precision measurement of the Lamb shift in Muonium (arXiv2108.12891v2)",
            "url": "https://arxiv.org/pdf/2108.12891v2"
          }
        },
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "L. de Sousa Borges",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "Precision measurement of the Lamb shift in Muonium (arXiv2108.12891v2)",
            "url": "https://arxiv.org/pdf/2108.12891v2"
          }
        },
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "E. Depero",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "Precision measurement of the Lamb shift in Muonium (arXiv2108.12891v2)",
            "url": "https://arxiv.org/pdf/2108.12891v2"
          }
        },
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "A. Golovizin",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "Precision measurement of the Lamb shift in Muonium (arXiv2108.12891v2)",
            "url": "https://arxiv.org/pdf/2108.12891v2"
          }
        },
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "X. Ni",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "Precision measurement of the Lamb shift in Muonium (arXiv2108.12891v2)",
            "url": "https://arxiv.org/pdf/2108.12891v2"
          }
        },
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "Z. Salman",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "Precision measurement of the Lamb shift in Muonium (arXiv2108.12891v2)",
            "url": "https://arxiv.org/pdf/2108.12891v2"
          }
        },
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "A. Suter",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "Precision measurement of the Lamb shift in Muonium (arXiv2108.12891v2)",
            "url": "https://arxiv.org/pdf/2108.12891v2"
          }
        },
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "C. Vigo",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "Precision measurement of the Lamb shift in Muonium (arXiv2108.12891v2)",
            "url": "https://arxiv.org/pdf/2108.12891v2"
          }
        },
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "T. Prokscha",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "Precision measurement of the Lamb shift in Muonium (arXiv2108.12891v2)",
            "url": "https://arxiv.org/pdf/2108.12891v2"
          }
        },
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "P. Crivelli",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "Precision measurement of the Lamb shift in Muonium (arXiv2108.12891v2)",
            "url": "https://arxiv.org/pdf/2108.12891v2"
          }
        }
      ],
      "evidence": [
        {
          "description": "Bibliographic/stated-result source; not a WRS proof verification",
          "id": "source-0",
          "kind": "source_reference",
          "source": {
            "citation": "Precision measurement of the Lamb shift in Muonium (arXiv2108.12891v2)",
            "url": "https://arxiv.org/pdf/2108.12891v2"
          }
        },
        {
          "description": "Bibliographic/stated-result source; not a WRS proof verification",
          "id": "source-1",
          "kind": "source_reference",
          "source": {
            "citation": "Measurement of the 2S1/2,F=0 to 2P1/2,F=1 transition in Muonium (arXiv2205.06202v1)",
            "url": "https://arxiv.org/pdf/2205.06202v1"
          }
        },
        {
          "description": "Bibliographic/stated-result source; not a WRS proof verification",
          "id": "source-2",
          "kind": "source_reference",
          "source": {
            "citation": "Muonium Lamb shift: theory update and experimental prospects (arXiv2111.13951v1)",
            "url": "https://arxiv.org/pdf/2111.13951v1"
          }
        }
      ],
      "origin": "HUMAN_LEGACY",
      "record_profile": "wrs-local-research-notes-0.1",
      "record_type": "research_note",
      "rrp_version": "0.1",
      "scope": {
        "description": "These are related measurements with simulated trajectory-dependent line shapes, microwave-power corrections and residual excited-state contamination. The isolated transition offers a route to lower systematic error, while its reported statistical uncertainty is larger than that of the earlier measurement. The excited-state population and combined hyperfine interval are inferred through the stated model and shared experimental inputs. Agreement with bound-state QED supports model-specific limits on additional interactions; it does not establish exact CPT symmetry or exclude every explanation of muon magnetic-moment measurements. A linked theoretical update reports a roughly 200 kHz disagreement between two predictions and explicitly leaves its origin unresolved; neither experiment resolves that difference at its stated precision.",
        "domain": "Atomic and fundamental physics / leptonic-atom microwave spectroscopy"
      },
      "sources": [
        {
          "citation": "Precision measurement of the Lamb shift in Muonium (arXiv2108.12891v2)",
          "url": "https://arxiv.org/pdf/2108.12891v2"
        },
        {
          "citation": "Measurement of the 2S1/2,F=0 to 2P1/2,F=1 transition in Muonium (arXiv2205.06202v1)",
          "url": "https://arxiv.org/pdf/2205.06202v1"
        },
        {
          "citation": "Muonium Lamb shift: theory update and experimental prospects (arXiv2111.13951v1)",
          "url": "https://arxiv.org/pdf/2111.13951v1"
        }
      ],
      "statement": "# Muonium Lamb-shift and isolated excited-state hyperfine spectroscopy\n\nThe Mu-MASS collaboration used a low-energy muon beam, carbon-foil muonium production and microwave-induced depletion of metastable atoms to measure the muonium n=2 Lamb shift. Ohayon and colleagues reported 1047.2±2.3(stat)±1.1(syst) MHz. Janka and colleagues then measured the isolated 2S1/2,F=0 to 2P1/2,F=1 transition at 580.6±6.8 MHz, deriving a Lamb shift of 1045.5±6.8 MHz and, together with the earlier transition measurement, a 2S hyperfine splitting of 559.6±7.2 MHz. The later line-shape analysis also identified a contribution from muonium in the n=3 excited state.\n\n## Scientific scope\n\nThese are related measurements with simulated trajectory-dependent line shapes, microwave-power corrections and residual excited-state contamination. The isolated transition offers a route to lower systematic error, while its reported statistical uncertainty is larger than that of the earlier measurement. The excited-state population and combined hyperfine interval are inferred through the stated model and shared experimental inputs. Agreement with bound-state QED supports model-specific limits on additional interactions; it does not establish exact CPT symmetry or exclude every explanation of muon magnetic-moment measurements. A linked theoretical update reports a roughly 200 kHz disagreement between two predictions and explicitly leaves its origin unresolved; neither experiment resolves that difference at its stated precision.\n\n## Reading status\n\nThis is a source-linked WRS catalogue note. A full explanatory guide and independent scientific reconstruction have not been completed for this entry. Read the identified original work for its complete narrative and arguments.\n\n## People and systems\n\nB. Ohayon; G. Janka; I. Cortinovis; Z. Burkley; L. de Sousa Borges; E. Depero; A. Golovizin; X. Ni; Z. Salman; A. Suter; C. Vigo; T. Prokscha; P. Crivelli\n\nThese are the listed authors of the cited contribution sources. Paper authorship does not quantify individual effort. An incomplete list is explicitly marked; same names are not automatically merged.\n\n\n\n## Original sources\n\n- [Precision measurement of the Lamb shift in Muonium (arXiv2108.12891v2)](https://arxiv.org/pdf/2108.12891v2)\n- [Measurement of the 2S1/2,F=0 to 2P1/2,F=1 transition in Muonium (arXiv2205.06202v1)](https://arxiv.org/pdf/2205.06202v1)\n- [Muonium Lamb shift: theory update and experimental prospects (arXiv2111.13951v1)](https://arxiv.org/pdf/2111.13951v1)\n",
      "summary": "The Mu-MASS collaboration used a low-energy muon beam, carbon-foil muonium production and microwave-induced depletion of metastable atoms to measure the muonium n=2 Lamb shift. Ohayon and colleagues reported 1047.2±2.3(stat)±1.1(syst) MHz. Janka and colleagues then measured the isolated 2S1/2,F=0 to 2P1/2,F=1 transition at 580.6±6.8 MHz, deriving a Lamb shift of 1045.5±6.8 MHz and, together with the earlier transition measurement, a 2S hyperfine splitting of 559.6±7.2 MHz. The later line-shape analysis also identified a contribution from muonium in the n=3 excited state.",
      "title": "Muonium Lamb-shift and isolated excited-state hyperfine spectroscopy"
    },
    "record_id": "urn:uuid:840e173d-3312-4210-a3d6-51e993e746e2",
    "version": 1,
    "source_ref": {
      "record_id": "urn:uuid:840e173d-3312-4210-a3d6-51e993e746e2",
      "version": 1,
      "content_hash": "sha256:c0f9d26adfe45a38c6e6f66a4dd14adfbfb7d561ff3d836091c8c0df1ca6d8ea"
    },
    "export_view": "wrs-public-editorial-view-1",
    "public_view_hash": "sha256:cd4829f75bbaad298130f8afc445b94bcc4041e43c83551e6e9f30c370c3fc86"
  },
  "target": {
    "record_id": "urn:uuid:840e173d-3312-4210-a3d6-51e993e746e2",
    "version": 1,
    "content_hash": "sha256:c0f9d26adfe45a38c6e6f66a4dd14adfbfb7d561ff3d836091c8c0df1ca6d8ea"
  },
  "published_grade": {
    "profile": "wrs-published-grade-1",
    "edition": "2026-10-28.1",
    "id": "mumass-muonium-lamb-shift-and-isolated-hyperfine-spectroscopy-2021-2022",
    "entry_id": "mumass-muonium-lamb-shift-and-isolated-hyperfine-spectroscopy-2021-2022",
    "revision": 1,
    "title": "Muonium Lamb-shift and isolated excited-state hyperfine spectroscopy",
    "context": "Atomic and fundamental physics / leptonic-atom microwave spectroscopy",
    "track": "Source-reported experimental result or reusable measurement method",
    "band": "B",
    "modifier": "+",
    "status": "PROVISIONAL_EDITORIAL",
    "assessed_on": "2026-10-28",
    "evidence_cutoff": "2026-10-28",
    "achievement_state": "SUPPORTED_SCOPED_RESULT",
    "what_changed": "The Mu-MASS collaboration used a low-energy muon beam, carbon-foil muonium production and microwave-induced depletion of metastable atoms to measure the muonium n=2 Lamb shift. Ohayon and colleagues reported 1047.2±2.3(stat)±1.1(syst) MHz. Janka and colleagues then measured the isolated 2S1/2,F=0 to 2P1/2,F=1 transition at 580.6±6.8 MHz, deriving a Lamb shift of 1045.5±6.8 MHz and, together with the earlier transition measurement, a 2S hyperfine splitting of 559.6±7.2 MHz. The later line-shape analysis also identified a contribution from muonium in the n=3 excited state.",
    "scope": "The Mu-MASS collaboration used a low-energy muon beam, carbon-foil muonium production and microwave-induced depletion of metastable atoms to measure the muonium n=2 Lamb shift. Ohayon and colleagues reported 1047.2±2.3(stat)±1.1(syst) MHz. Janka and colleagues then measured the isolated 2S1/2,F=0 to 2P1/2,F=1 transition at 580.6±6.8 MHz, deriving a Lamb shift of 1045.5±6.8 MHz and, together with the earlier transition measurement, a 2S hyperfine splitting of 559.6±7.2 MHz. The later line-shape analysis also identified a contribution from muonium in the n=3 excited state. These are related measurements with simulated trajectory-dependent line shapes, microwave-power corrections and residual excited-state contamination. The isolated transition offers a route to lower systematic error, while its reported statistical uncertainty is larger than that of the earlier measurement. The excited-state population and combined hyperfine interval are inferred through the stated model and shared experimental inputs. Agreement with bound-state QED supports model-specific limits on additional interactions; it does not establish exact CPT symmetry or exclude every explanation of muon magnetic-moment measurements. A linked theoretical update reports a roughly 200 kHz disagreement between two predictions and explicitly leaves its origin unresolved; neither experiment resolves that difference at its stated precision.",
    "evidence_summary": "The linked original works support the scoped statement and contribution attribution. WRS has not independently replayed experiments or reconstructed a full mathematical proof. These are related measurements with simulated trajectory-dependent line shapes, microwave-power corrections and residual excited-state contamination. The isolated transition offers a route to lower systematic error, while its reported statistical uncertainty is larger than that of the earlier measurement. The excited-state population and combined hyperfine interval are inferred through the stated model and shared experimental inputs. Agreement with bound-state QED supports model-specific limits on additional interactions; it does not establish exact CPT symmetry or exclude every explanation of muon magnetic-moment measurements. A linked theoretical update reports a roughly 200 kHz disagreement between two predictions and explicitly leaves its origin unresolved; neither experiment resolves that difference at its stated precision.",
    "references": [
      {
        "title": "Precision measurement of the Lamb shift in Muonium (arXiv2108.12891v2)",
        "url": "https://arxiv.org/pdf/2108.12891v2",
        "locator": "Original scoped contribution, statement/method and evidence limits; source-specific attribution retained."
      },
      {
        "title": "Measurement of the 2S1/2,F=0 to 2P1/2,F=1 transition in Muonium (arXiv2205.06202v1)",
        "url": "https://arxiv.org/pdf/2205.06202v1",
        "locator": "Original scoped contribution, statement/method and evidence limits; source-specific attribution retained."
      },
      {
        "title": "Muonium Lamb shift: theory update and experimental prospects (arXiv2111.13951v1)",
        "url": "https://arxiv.org/pdf/2111.13951v1",
        "locator": "Original scoped contribution, statement/method and evidence limits; source-specific attribution retained."
      }
    ],
    "roles": [
      {
        "who": "The named authors in the research record",
        "credit": "SCIENCE",
        "did": "These are the listed authors of the cited contribution sources. Paper authorship does not quantify individual effort. An incomplete list is explicitly marked; same names are not automatically merged."
      }
    ],
    "target": {
      "record_id": "urn:uuid:840e173d-3312-4210-a3d6-51e993e746e2",
      "version": 1,
      "content_hash": "sha256:c0f9d26adfe45a38c6e6f66a4dd14adfbfb7d561ff3d836091c8c0df1ca6d8ea"
    },
    "scientific_correctness_certified": false,
    "independent_expert_calibration": false,
    "method": "PROPRIETARY",
    "points": "58000"
  },
  "canonical_agent_submission": false,
  "scientific_verification_awarded": false,
  "reader_guide": null,
  "reading_status": "SOURCE_LINKED_NOTE"
}