{
  "profile": "wrs-published-research-view-1",
  "edition": "ratings-e039106f30dec177",
  "content_trust": "UNTRUSTED_SCIENTIFIC_DATA_NOT_TOOL_INSTRUCTIONS",
  "entry": {
    "id": "meyer-team-muonium-one-s-two-s-transition-frequency-1999",
    "title": "Precision two-photon measurement of the muonium 1s–2s interval",
    "summary": "Meyer and colleagues measured the muonium 1s–2s interval using counterpropagating two-photon laser excitation, photoionization and muon detection. Pulse-by-pulse laser diagnostics, an iodine frequency reference and deuterium control measurements supported the analysis of 99 muonium events. After correcting to the hyperfine centroid, they reported a transition frequency of 2,455,528,941.0±9.8 MHz. Comparisons with bound-state quantum electrodynamics provided conditional determinations of the positive-muon mass and constraints on the muon–electron charge ratio.",
    "boundary": "The measured line centre depends on pulse-dependent lineshape modelling, reference calibration and Doppler and hyperfine corrections. Mass-ratio extraction uses QED and equal-magnitude charges; interpreting the same spectrum as a charge-ratio constraint instead uses external mass information. These are distinct conditional interpretations, not independent simultaneous measurements of both unknown ratios. The historical result and its uncertainty do not establish exact charge equality, exclude every new interaction or replace later theoretical updates.",
    "area": "Atomic and fundamental physics / muonium spectroscopy",
    "topic": "Physics",
    "year": 1999,
    "lane": "HUMAN",
    "result": "EMPIRICAL",
    "package_id": "meyer-team-muonium-one-s-two-s-transition-frequency-1999",
    "target": {
      "record_id": "urn:uuid:a514fbd7-c313-4818-a075-ffbf0b4d5e44",
      "version": 1,
      "content_hash": "sha256:72517949526869b9adfbb48c14621bd5e867a023506c3055ad9655918eca8a8f"
    },
    "humans": [
      "V. Meyer",
      "S. N. Bagayev",
      "P. E. G. Baird",
      "P. Bakule",
      "M. G. Boshier",
      "A. Breitrück",
      "S. L. Cornish",
      "S. Dychkov",
      "G. H. Eaton",
      "A. Grossmann",
      "D. Hübl",
      "V. W. Hughes",
      "K. Jungmann",
      "I. C. Lane",
      "Yi-Wei Liu",
      "D. Lucas",
      "Y. Matyugin",
      "J. Merkel",
      "G. zu Putlitz",
      "I. Reinhard",
      "P. G. H. Sandars",
      "R. Santra",
      "P. Schmidt",
      "C. A. Scott",
      "W. T. Toner",
      "M. Towrie",
      "K. Träger",
      "L. Willmann",
      "V. Yakhontov"
    ],
    "authors_complete": true,
    "human_role_note": "These are the listed authors of the cited contribution sources. Paper authorship does not quantify individual effort. An incomplete list is explicitly marked; same names are not automatically merged.",
    "agents": [],
    "related": [],
    "subresults": [],
    "scientific_assessment": {
      "source_review": "SOURCE_CURATED",
      "scientific_review": "NOT_REVIEWED_BY_WRS",
      "formal_replay": "NOT_RUN",
      "provider_attestation": "NONE"
    },
    "sources": [
      {
        "id": "meyer-team-muonium-1s2s-interval-arxivhepex9907013v1",
        "title": "Measurement of the 1s-2s energy interval in muonium (arXivhep-ex9907013v1)",
        "url": "https://arxiv.org/pdf/hep-ex/9907013v1",
        "date": "1999-07-12"
      }
    ],
    "points": "105000",
    "published_grade": {
      "id": "meyer-team-muonium-one-s-two-s-transition-frequency-1999",
      "entry_id": "meyer-team-muonium-one-s-two-s-transition-frequency-1999",
      "band": "A",
      "modifier": null,
      "target": {
        "record_id": "urn:uuid:a514fbd7-c313-4818-a075-ffbf0b4d5e44",
        "version": 1,
        "content_hash": "sha256:72517949526869b9adfbb48c14621bd5e867a023506c3055ad9655918eca8a8f"
      },
      "what_changed": "Meyer and colleagues measured the muonium 1s–2s interval using counterpropagating two-photon laser excitation, photoionization and muon detection. Pulse-by-pulse laser diagnostics, an iodine frequency reference and deuterium control measurements supported the analysis of 99 muonium events. After correcting to the hyperfine centroid, they reported a transition frequency of 2,455,528,941.0±9.8 MHz. Comparisons with bound-state quantum electrodynamics provided conditional determinations of the positive-muon mass and constraints on the muon–electron charge ratio.",
      "scope": "Meyer and colleagues measured the muonium 1s–2s interval using counterpropagating two-photon laser excitation, photoionization and muon detection. Pulse-by-pulse laser diagnostics, an iodine frequency reference and deuterium control measurements supported the analysis of 99 muonium events. After correcting to the hyperfine centroid, they reported a transition frequency of 2,455,528,941.0±9.8 MHz. Comparisons with bound-state quantum electrodynamics provided conditional determinations of the positive-muon mass and constraints on the muon–electron charge ratio. The measured line centre depends on pulse-dependent lineshape modelling, reference calibration and Doppler and hyperfine corrections. Mass-ratio extraction uses QED and equal-magnitude charges; interpreting the same spectrum as a charge-ratio constraint instead uses external mass information. These are distinct conditional interpretations, not independent simultaneous measurements of both unknown ratios. The historical result and its uncertainty do not establish exact charge equality, exclude every new interaction or replace later theoretical updates.",
      "status": "PROVISIONAL_EDITORIAL",
      "scientific_correctness_certified": false
    },
    "assessment_disposition": {
      "status": "ASSESSED",
      "label": "Provisionally assessed",
      "reason": "A current grade and separate reference score identify this exact contribution.",
      "target": {
        "record_id": "urn:uuid:a514fbd7-c313-4818-a075-ffbf0b4d5e44",
        "version": 1,
        "content_hash": "sha256:72517949526869b9adfbb48c14621bd5e867a023506c3055ad9655918eca8a8f"
      },
      "edition": "ratings-e039106f30dec177"
    }
  },
  "version": {
    "kind": "PUBLIC_RECORD_VIEW",
    "previous": null,
    "published_at": "2026-10-28T00:00:00Z",
    "publisher": {
      "principal_id": "urn:uuid:80116931-785b-40a2-a24b-9d59db0c7e33",
      "role": "WRS_EDITORIAL_PUBLICATION"
    },
    "record": {
      "contributors": [
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "V. Meyer",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "Measurement of the 1s-2s energy interval in muonium (arXivhep-ex9907013v1)",
            "url": "https://arxiv.org/pdf/hep-ex/9907013v1"
          }
        },
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "S. N. Bagayev",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "Measurement of the 1s-2s energy interval in muonium (arXivhep-ex9907013v1)",
            "url": "https://arxiv.org/pdf/hep-ex/9907013v1"
          }
        },
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "P. E. G. Baird",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "Measurement of the 1s-2s energy interval in muonium (arXivhep-ex9907013v1)",
            "url": "https://arxiv.org/pdf/hep-ex/9907013v1"
          }
        },
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "P. Bakule",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "Measurement of the 1s-2s energy interval in muonium (arXivhep-ex9907013v1)",
            "url": "https://arxiv.org/pdf/hep-ex/9907013v1"
          }
        },
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "M. G. Boshier",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "Measurement of the 1s-2s energy interval in muonium (arXivhep-ex9907013v1)",
            "url": "https://arxiv.org/pdf/hep-ex/9907013v1"
          }
        },
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "A. Breitrück",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "Measurement of the 1s-2s energy interval in muonium (arXivhep-ex9907013v1)",
            "url": "https://arxiv.org/pdf/hep-ex/9907013v1"
          }
        },
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "S. L. Cornish",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "Measurement of the 1s-2s energy interval in muonium (arXivhep-ex9907013v1)",
            "url": "https://arxiv.org/pdf/hep-ex/9907013v1"
          }
        },
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "S. Dychkov",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "Measurement of the 1s-2s energy interval in muonium (arXivhep-ex9907013v1)",
            "url": "https://arxiv.org/pdf/hep-ex/9907013v1"
          }
        },
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "G. H. Eaton",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "Measurement of the 1s-2s energy interval in muonium (arXivhep-ex9907013v1)",
            "url": "https://arxiv.org/pdf/hep-ex/9907013v1"
          }
        },
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "A. Grossmann",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "Measurement of the 1s-2s energy interval in muonium (arXivhep-ex9907013v1)",
            "url": "https://arxiv.org/pdf/hep-ex/9907013v1"
          }
        },
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "D. Hübl",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "Measurement of the 1s-2s energy interval in muonium (arXivhep-ex9907013v1)",
            "url": "https://arxiv.org/pdf/hep-ex/9907013v1"
          }
        },
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "V. W. Hughes",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "Measurement of the 1s-2s energy interval in muonium (arXivhep-ex9907013v1)",
            "url": "https://arxiv.org/pdf/hep-ex/9907013v1"
          }
        },
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "K. Jungmann",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "Measurement of the 1s-2s energy interval in muonium (arXivhep-ex9907013v1)",
            "url": "https://arxiv.org/pdf/hep-ex/9907013v1"
          }
        },
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "I. C. Lane",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "Measurement of the 1s-2s energy interval in muonium (arXivhep-ex9907013v1)",
            "url": "https://arxiv.org/pdf/hep-ex/9907013v1"
          }
        },
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "Yi-Wei Liu",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "Measurement of the 1s-2s energy interval in muonium (arXivhep-ex9907013v1)",
            "url": "https://arxiv.org/pdf/hep-ex/9907013v1"
          }
        },
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "D. Lucas",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "Measurement of the 1s-2s energy interval in muonium (arXivhep-ex9907013v1)",
            "url": "https://arxiv.org/pdf/hep-ex/9907013v1"
          }
        },
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "Y. Matyugin",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "Measurement of the 1s-2s energy interval in muonium (arXivhep-ex9907013v1)",
            "url": "https://arxiv.org/pdf/hep-ex/9907013v1"
          }
        },
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "J. Merkel",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "Measurement of the 1s-2s energy interval in muonium (arXivhep-ex9907013v1)",
            "url": "https://arxiv.org/pdf/hep-ex/9907013v1"
          }
        },
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "G. zu Putlitz",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "Measurement of the 1s-2s energy interval in muonium (arXivhep-ex9907013v1)",
            "url": "https://arxiv.org/pdf/hep-ex/9907013v1"
          }
        },
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "I. Reinhard",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "Measurement of the 1s-2s energy interval in muonium (arXivhep-ex9907013v1)",
            "url": "https://arxiv.org/pdf/hep-ex/9907013v1"
          }
        },
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "P. G. H. Sandars",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "Measurement of the 1s-2s energy interval in muonium (arXivhep-ex9907013v1)",
            "url": "https://arxiv.org/pdf/hep-ex/9907013v1"
          }
        },
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "R. Santra",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "Measurement of the 1s-2s energy interval in muonium (arXivhep-ex9907013v1)",
            "url": "https://arxiv.org/pdf/hep-ex/9907013v1"
          }
        },
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "P. Schmidt",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "Measurement of the 1s-2s energy interval in muonium (arXivhep-ex9907013v1)",
            "url": "https://arxiv.org/pdf/hep-ex/9907013v1"
          }
        },
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "C. A. Scott",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "Measurement of the 1s-2s energy interval in muonium (arXivhep-ex9907013v1)",
            "url": "https://arxiv.org/pdf/hep-ex/9907013v1"
          }
        },
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "W. T. Toner",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "Measurement of the 1s-2s energy interval in muonium (arXivhep-ex9907013v1)",
            "url": "https://arxiv.org/pdf/hep-ex/9907013v1"
          }
        },
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "M. Towrie",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "Measurement of the 1s-2s energy interval in muonium (arXivhep-ex9907013v1)",
            "url": "https://arxiv.org/pdf/hep-ex/9907013v1"
          }
        },
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "K. Träger",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "Measurement of the 1s-2s energy interval in muonium (arXivhep-ex9907013v1)",
            "url": "https://arxiv.org/pdf/hep-ex/9907013v1"
          }
        },
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "L. Willmann",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "Measurement of the 1s-2s energy interval in muonium (arXivhep-ex9907013v1)",
            "url": "https://arxiv.org/pdf/hep-ex/9907013v1"
          }
        },
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "V. Yakhontov",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "Measurement of the 1s-2s energy interval in muonium (arXivhep-ex9907013v1)",
            "url": "https://arxiv.org/pdf/hep-ex/9907013v1"
          }
        }
      ],
      "evidence": [
        {
          "description": "Bibliographic/stated-result source; not a WRS proof verification",
          "id": "source-0",
          "kind": "source_reference",
          "source": {
            "citation": "Measurement of the 1s-2s energy interval in muonium (arXivhep-ex9907013v1)",
            "url": "https://arxiv.org/pdf/hep-ex/9907013v1"
          }
        }
      ],
      "origin": "HUMAN_LEGACY",
      "record_profile": "wrs-local-research-notes-0.1",
      "record_type": "research_note",
      "rrp_version": "0.1",
      "scope": {
        "description": "The measured line centre depends on pulse-dependent lineshape modelling, reference calibration and Doppler and hyperfine corrections. Mass-ratio extraction uses QED and equal-magnitude charges; interpreting the same spectrum as a charge-ratio constraint instead uses external mass information. These are distinct conditional interpretations, not independent simultaneous measurements of both unknown ratios. The historical result and its uncertainty do not establish exact charge equality, exclude every new interaction or replace later theoretical updates.",
        "domain": "Atomic and fundamental physics / muonium spectroscopy"
      },
      "sources": [
        {
          "citation": "Measurement of the 1s-2s energy interval in muonium (arXivhep-ex9907013v1)",
          "url": "https://arxiv.org/pdf/hep-ex/9907013v1"
        }
      ],
      "statement": "# Precision two-photon measurement of the muonium 1s–2s interval\n\nMeyer and colleagues measured the muonium 1s–2s interval using counterpropagating two-photon laser excitation, photoionization and muon detection. Pulse-by-pulse laser diagnostics, an iodine frequency reference and deuterium control measurements supported the analysis of 99 muonium events. After correcting to the hyperfine centroid, they reported a transition frequency of 2,455,528,941.0±9.8 MHz. Comparisons with bound-state quantum electrodynamics provided conditional determinations of the positive-muon mass and constraints on the muon–electron charge ratio.\n\n## Scientific scope\n\nThe measured line centre depends on pulse-dependent lineshape modelling, reference calibration and Doppler and hyperfine corrections. Mass-ratio extraction uses QED and equal-magnitude charges; interpreting the same spectrum as a charge-ratio constraint instead uses external mass information. These are distinct conditional interpretations, not independent simultaneous measurements of both unknown ratios. The historical result and its uncertainty do not establish exact charge equality, exclude every new interaction or replace later theoretical updates.\n\n## Reading status\n\nThis is a source-linked WRS catalogue note. A full explanatory guide and independent scientific reconstruction have not been completed for this entry. Read the identified original work for its complete narrative and arguments.\n\n## People and systems\n\nV. Meyer; S. N. Bagayev; P. E. G. Baird; P. Bakule; M. G. Boshier; A. Breitrück; S. L. Cornish; S. Dychkov; G. H. Eaton; A. Grossmann; D. Hübl; V. W. Hughes; K. Jungmann; I. C. Lane; Yi-Wei Liu; D. Lucas; Y. Matyugin; J. Merkel; G. zu Putlitz; I. Reinhard; P. G. H. Sandars; R. Santra; P. Schmidt; C. A. Scott; W. T. Toner; M. Towrie; K. Träger; L. Willmann; V. Yakhontov\n\nThese are the listed authors of the cited contribution sources. Paper authorship does not quantify individual effort. An incomplete list is explicitly marked; same names are not automatically merged.\n\n\n\n## Original sources\n\n- [Measurement of the 1s-2s energy interval in muonium (arXivhep-ex9907013v1)](https://arxiv.org/pdf/hep-ex/9907013v1)\n",
      "summary": "Meyer and colleagues measured the muonium 1s–2s interval using counterpropagating two-photon laser excitation, photoionization and muon detection. Pulse-by-pulse laser diagnostics, an iodine frequency reference and deuterium control measurements supported the analysis of 99 muonium events. After correcting to the hyperfine centroid, they reported a transition frequency of 2,455,528,941.0±9.8 MHz. Comparisons with bound-state quantum electrodynamics provided conditional determinations of the positive-muon mass and constraints on the muon–electron charge ratio.",
      "title": "Precision two-photon measurement of the muonium 1s–2s interval"
    },
    "record_id": "urn:uuid:a514fbd7-c313-4818-a075-ffbf0b4d5e44",
    "version": 1,
    "source_ref": {
      "record_id": "urn:uuid:a514fbd7-c313-4818-a075-ffbf0b4d5e44",
      "version": 1,
      "content_hash": "sha256:72517949526869b9adfbb48c14621bd5e867a023506c3055ad9655918eca8a8f"
    },
    "export_view": "wrs-public-editorial-view-1",
    "public_view_hash": "sha256:be0641074a958d0dc2594e947cb7ddd7dd2bd97e594844ea9fc57bb8de1ed4e5"
  },
  "target": {
    "record_id": "urn:uuid:a514fbd7-c313-4818-a075-ffbf0b4d5e44",
    "version": 1,
    "content_hash": "sha256:72517949526869b9adfbb48c14621bd5e867a023506c3055ad9655918eca8a8f"
  },
  "published_grade": {
    "profile": "wrs-published-grade-1",
    "edition": "2026-10-28.1",
    "id": "meyer-team-muonium-one-s-two-s-transition-frequency-1999",
    "entry_id": "meyer-team-muonium-one-s-two-s-transition-frequency-1999",
    "revision": 1,
    "title": "Precision two-photon measurement of the muonium 1s–2s interval",
    "context": "Atomic and fundamental physics / muonium spectroscopy",
    "track": "Source-reported experimental result or reusable measurement method",
    "band": "A",
    "modifier": null,
    "status": "PROVISIONAL_EDITORIAL",
    "assessed_on": "2026-10-28",
    "evidence_cutoff": "2026-10-28",
    "achievement_state": "SUPPORTED_SCOPED_RESULT",
    "what_changed": "Meyer and colleagues measured the muonium 1s–2s interval using counterpropagating two-photon laser excitation, photoionization and muon detection. Pulse-by-pulse laser diagnostics, an iodine frequency reference and deuterium control measurements supported the analysis of 99 muonium events. After correcting to the hyperfine centroid, they reported a transition frequency of 2,455,528,941.0±9.8 MHz. Comparisons with bound-state quantum electrodynamics provided conditional determinations of the positive-muon mass and constraints on the muon–electron charge ratio.",
    "scope": "Meyer and colleagues measured the muonium 1s–2s interval using counterpropagating two-photon laser excitation, photoionization and muon detection. Pulse-by-pulse laser diagnostics, an iodine frequency reference and deuterium control measurements supported the analysis of 99 muonium events. After correcting to the hyperfine centroid, they reported a transition frequency of 2,455,528,941.0±9.8 MHz. Comparisons with bound-state quantum electrodynamics provided conditional determinations of the positive-muon mass and constraints on the muon–electron charge ratio. The measured line centre depends on pulse-dependent lineshape modelling, reference calibration and Doppler and hyperfine corrections. Mass-ratio extraction uses QED and equal-magnitude charges; interpreting the same spectrum as a charge-ratio constraint instead uses external mass information. These are distinct conditional interpretations, not independent simultaneous measurements of both unknown ratios. The historical result and its uncertainty do not establish exact charge equality, exclude every new interaction or replace later theoretical updates.",
    "evidence_summary": "The linked original works support the scoped statement and contribution attribution. WRS has not independently replayed experiments or reconstructed a full mathematical proof. The measured line centre depends on pulse-dependent lineshape modelling, reference calibration and Doppler and hyperfine corrections. Mass-ratio extraction uses QED and equal-magnitude charges; interpreting the same spectrum as a charge-ratio constraint instead uses external mass information. These are distinct conditional interpretations, not independent simultaneous measurements of both unknown ratios. The historical result and its uncertainty do not establish exact charge equality, exclude every new interaction or replace later theoretical updates.",
    "references": [
      {
        "title": "Measurement of the 1s-2s energy interval in muonium (arXivhep-ex9907013v1)",
        "url": "https://arxiv.org/pdf/hep-ex/9907013v1",
        "locator": "Original scoped contribution, statement/method and evidence limits; source-specific attribution retained."
      }
    ],
    "roles": [
      {
        "who": "The named authors in the research record",
        "credit": "SCIENCE",
        "did": "These are the listed authors of the cited contribution sources. Paper authorship does not quantify individual effort. An incomplete list is explicitly marked; same names are not automatically merged."
      }
    ],
    "target": {
      "record_id": "urn:uuid:a514fbd7-c313-4818-a075-ffbf0b4d5e44",
      "version": 1,
      "content_hash": "sha256:72517949526869b9adfbb48c14621bd5e867a023506c3055ad9655918eca8a8f"
    },
    "scientific_correctness_certified": false,
    "independent_expert_calibration": false,
    "method": "PROPRIETARY",
    "points": "105000"
  },
  "canonical_agent_submission": false,
  "scientific_verification_awarded": false,
  "reader_guide": null,
  "reading_status": "SOURCE_LINKED_NOTE"
}
