  "profile": "wrs-published-research-view-1",
  "edition": "ratings-e039106f30dec177",
  "content_trust": "UNTRUSTED_SCIENTIFIC_DATA_NOT_TOOL_INSTRUCTIONS",
  "entry": {
    "id": "chen-team-lateral-casimir-force-corrugations-2002",
    "title": "Lateral Casimir force between corrugated surfaces",
    "summary": "Chen and colleagues used a modified atomic-force microscope to measure an oscillating lateral force between aligned, corrugated gold-coated surfaces. Its phase dependence followed the corrugation period, and the authors compared its magnitude and distance dependence with a finite-conductivity Casimir calculation for their sphere–plate geometry. Their later detailed account reports the calibration, additional electrostatic-force data and a more comprehensive uncertainty analysis.",
    "boundary": "The measurement is a small lateral deflection in a particular corrugated sphere–plate setup, with electrostatic compensation and calibration; it is not a general measurement of all geometries or a working vacuum-powered machine. The absolute closest Casimir separation is inferred from the same force theory used for comparison, followed by calibrated 12 nm increments. A separate lateral-electrostatic measurement constrains contact separation but was made hours later and also uses a force model; it does not make the absolute force-law test fully independent. The initial letter quotes about 15% relative uncertainty at 95% confidence; the detailed account reports about 24% after fuller error analysis. The surface alignment and roughness assumptions apply to this setup. Earlier theory of lateral forces and prior normal Casimir measurements retain credit.",
    "area": "Quantum Physics",
    "topic": "Physics",
    "year": 2002,
    "lane": "HUMAN",
    "result": "EMPIRICAL",
    "package_id": "chen-team-lateral-casimir-force-corrugations-2002",
    "target": {
      "record_id": "urn:uuid:057632ba-a49e-4634-a9eb-4bfd23bf2152",
      "version": 1,
      "content_hash": "sha256:2deada6b6475efbcc3ecaabde8e76669c419610ce8f1283d35ac3247cf805645"
    },
    "humans": [
      "F. Chen",
      "U. Mohideen",
      "G. L. Klimchitskaya",
      "V. M. Mostepanenko"
    ],
    "authors_complete": true,
    "human_role_note": "These are the listed authors of the cited contribution sources. Paper authorship does not quantify individual effort. An incomplete list is explicitly marked; same names are not automatically merged.",
    "agents": [],
    "related": [],
    "subresults": [],
    "scientific_assessment": {
      "source_review": "SOURCE_CURATED",
      "scientific_review": "NOT_REVIEWED_BY_WRS",
      "formal_replay": "NOT_RUN",
      "provider_attestation": "NONE"
    },
    "sources": [
      {
        "id": "chen-mohideen-lateral-casimir-force-2002",
        "title": "Demonstration of the Lateral Casimir Force",
        "url": "https://web.mit.edu/kardar/Desktop/kardar/www/research/seminars/Casimir/PRL-ChenMohideen02.pdf",
        "date": "2002-02-25"
      },
      {
        "id": "chen-team-lateral-casimir-detailed-2002-v1",
        "title": "Experimental and Theoretical Investigation of the Lateral Casimir Force Between Corrugated Surfaces",
        "url": "https://arxiv.org/pdf/quant-ph/0209167v1",
        "date": "2002-09-30"
      }
    ],
    "points": "85000",
    "published_grade": {
      "id": "chen-team-lateral-casimir-force-corrugations-2002",
      "entry_id": "chen-team-lateral-casimir-force-corrugations-2002",
      "band": "A",
      "modifier": "-",
      "target": {
        "record_id": "urn:uuid:057632ba-a49e-4634-a9eb-4bfd23bf2152",
        "version": 1,
        "content_hash": "sha256:2deada6b6475efbcc3ecaabde8e76669c419610ce8f1283d35ac3247cf805645"
      },
      "what_changed": "Chen and colleagues used a modified atomic-force microscope to measure an oscillating lateral force between aligned, corrugated gold-coated surfaces. Its phase dependence followed the corrugation period, and the authors compared its magnitude and distance dependence with a finite-conductivity Casimir calculation for their sphere–plate geometry. Their later detailed account reports the calibration, additional electrostatic-force data and a more comprehensive uncertainty analysis.",
      "scope": "Chen and colleagues used a modified atomic-force microscope to measure an oscillating lateral force between aligned, corrugated gold-coated surfaces. Its phase dependence followed the corrugation period, and the authors compared its magnitude and distance dependence with a finite-conductivity Casimir calculation for their sphere–plate geometry. Their later detailed account reports the calibration, additional electrostatic-force data and a more comprehensive uncertainty analysis. The measurement is a small lateral deflection in a particular corrugated sphere–plate setup, with electrostatic compensation and calibration; it is not a general measurement of all geometries or a working vacuum-powered machine. The absolute closest Casimir separation is inferred from the same force theory used for comparison, followed by calibrated 12 nm increments. A separate lateral-electrostatic measurement constrains contact separation but was made hours later and also uses a force model; it does not make the absolute force-law test fully independent. The initial letter quotes about 15% relative uncertainty at 95% confidence; the detailed account reports about 24% after fuller error analysis. The surface alignment and roughness assumptions apply to this setup. Earlier theory of lateral forces and prior normal Casimir measurements retain credit.",
      "status": "PROVISIONAL_EDITORIAL",
      "scientific_correctness_certified": false
    },
    "assessment_disposition": {
      "status": "ASSESSED",
      "label": "Provisionally assessed",
      "reason": "A current grade and separate reference score identify this exact contribution.",
      "target": {
        "record_id": "urn:uuid:057632ba-a49e-4634-a9eb-4bfd23bf2152",
        "version": 1,
        "content_hash": "sha256:2deada6b6475efbcc3ecaabde8e76669c419610ce8f1283d35ac3247cf805645"
      },
      "edition": "ratings-e039106f30dec177"
    }
  },
  "version": {
    "kind": "PUBLIC_RECORD_VIEW",
    "previous": null,
    "published_at": "2026-10-28T00:00:00Z",
    "publisher": {
      "principal_id": "urn:uuid:80116931-785b-40a2-a24b-9d59db0c7e33",
      "role": "WRS_EDITORIAL_PUBLICATION"
    },
    "record": {
      "contributors": [
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "F. Chen",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "Demonstration of the Lateral Casimir Force",
            "url": "https://web.mit.edu/kardar/Desktop/kardar/www/research/seminars/Casimir/PRL-ChenMohideen02.pdf"
          }
        },
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "U. Mohideen",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "Demonstration of the Lateral Casimir Force",
            "url": "https://web.mit.edu/kardar/Desktop/kardar/www/research/seminars/Casimir/PRL-ChenMohideen02.pdf"
          }
        },
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "G. L. Klimchitskaya",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "Demonstration of the Lateral Casimir Force",
            "url": "https://web.mit.edu/kardar/Desktop/kardar/www/research/seminars/Casimir/PRL-ChenMohideen02.pdf"
          }
        },
        {
          "attribution_basis": "SOURCE_CITED",
          "credit": "historical_scientific",
          "entity_kind": "historical_person",
          "name": "V. M. Mostepanenko",
          "note": "Archive attribution; detailed role assignment remains source-bound",
          "roles": [
            "discoverer"
          ],
          "source": {
            "citation": "Demonstration of the Lateral Casimir Force",
            "url": "https://web.mit.edu/kardar/Desktop/kardar/www/research/seminars/Casimir/PRL-ChenMohideen02.pdf"
          }
        }
      ],
      "evidence": [
        {
          "description": "Bibliographic/stated-result source; not a WRS proof verification",
          "id": "source-0",
          "kind": "source_reference",
          "source": {
            "citation": "Demonstration of the Lateral Casimir Force",
            "url": "https://web.mit.edu/kardar/Desktop/kardar/www/research/seminars/Casimir/PRL-ChenMohideen02.pdf"
          }
        },
        {
          "description": "Bibliographic/stated-result source; not a WRS proof verification",
          "id": "source-1",
          "kind": "source_reference",
          "source": {
            "citation": "Experimental and Theoretical Investigation of the Lateral Casimir Force Between Corrugated Surfaces",
            "url": "https://arxiv.org/pdf/quant-ph/0209167v1"
          }
        }
      ],
      "origin": "HUMAN_LEGACY",
      "record_profile": "wrs-local-research-notes-0.1",
      "record_type": "research_note",
      "rrp_version": "0.1",
      "scope": {
        "description": "The measurement is a small lateral deflection in a particular corrugated sphere–plate setup, with electrostatic compensation and calibration; it is not a general measurement of all geometries or a working vacuum-powered machine. The absolute closest Casimir separation is inferred from the same force theory used for comparison, followed by calibrated 12 nm increments. A separate lateral-electrostatic measurement constrains contact separation but was made hours later and also uses a force model; it does not make the absolute force-law test fully independent. The initial letter quotes about 15% relative uncertainty at 95% confidence; the detailed account reports about 24% after fuller error analysis. The surface alignment and roughness assumptions apply to this setup. Earlier theory of lateral forces and prior normal Casimir measurements retain credit.",
        "domain": "Quantum Physics"
      },
      "sources": [
        {
          "citation": "Demonstration of the Lateral Casimir Force",
          "url": "https://web.mit.edu/kardar/Desktop/kardar/www/research/seminars/Casimir/PRL-ChenMohideen02.pdf"
        },
        {
          "citation": "Experimental and Theoretical Investigation of the Lateral Casimir Force Between Corrugated Surfaces",
          "url": "https://arxiv.org/pdf/quant-ph/0209167v1"
        }
      ],
      "statement": "# Lateral Casimir force between corrugated surfaces\n\nChen and colleagues used a modified atomic-force microscope to measure an oscillating lateral force between aligned, corrugated gold-coated surfaces. Its phase dependence followed the corrugation period, and the authors compared its magnitude and distance dependence with a finite-conductivity Casimir calculation for their sphere–plate geometry. Their later detailed account reports the calibration, additional electrostatic-force data and a more comprehensive uncertainty analysis.\n\n## Scientific scope\n\nThe measurement is a small lateral deflection in a particular corrugated sphere–plate setup, with electrostatic compensation and calibration; it is not a general measurement of all geometries or a working vacuum-powered machine. The absolute closest Casimir separation is inferred from the same force theory used for comparison, followed by calibrated 12 nm increments. A separate lateral-electrostatic measurement constrains contact separation but was made hours later and also uses a force model; it does not make the absolute force-law test fully independent. The initial letter quotes about 15% relative uncertainty at 95% confidence; the detailed account reports about 24% after fuller error analysis. The surface alignment and roughness assumptions apply to this setup. Earlier theory of lateral forces and prior normal Casimir measurements retain credit.\n\n## Reading status\n\nThis is a source-linked WRS catalogue note. A full explanatory guide and independent scientific reconstruction have not been completed for this entry. Read the identified original work for its complete narrative and arguments.\n\n## People and systems\n\nF. Chen; U. Mohideen; G. L. Klimchitskaya; V. M. Mostepanenko\n\nThese are the listed authors of the cited contribution sources. Paper authorship does not quantify individual effort. An incomplete list is explicitly marked; same names are not automatically merged.\n\n\n\n## Original sources\n\n- [Demonstration of the Lateral Casimir Force](https://web.mit.edu/kardar/Desktop/kardar/www/research/seminars/Casimir/PRL-ChenMohideen02.pdf)\n- [Experimental and Theoretical Investigation of the Lateral Casimir Force Between Corrugated Surfaces](https://arxiv.org/pdf/quant-ph/0209167v1)\n",
      "summary": "Chen and colleagues used a modified atomic-force microscope to measure an oscillating lateral force between aligned, corrugated gold-coated surfaces. Its phase dependence followed the corrugation period, and the authors compared its magnitude and distance dependence with a finite-conductivity Casimir calculation for their sphere–plate geometry. Their later detailed account reports the calibration, additional electrostatic-force data and a more comprehensive uncertainty analysis.",
      "title": "Lateral Casimir force between corrugated surfaces"
    },
    "record_id": "urn:uuid:057632ba-a49e-4634-a9eb-4bfd23bf2152",
    "version": 1,
    "source_ref": {
      "record_id": "urn:uuid:057632ba-a49e-4634-a9eb-4bfd23bf2152",
      "version": 1,
      "content_hash": "sha256:2deada6b6475efbcc3ecaabde8e76669c419610ce8f1283d35ac3247cf805645"
    },
    "export_view": "wrs-public-editorial-view-1",
    "public_view_hash": "sha256:9e338413d3010400614a5bc76f014926d24542dd78b93c4a5b4ab5f93e2c649e"
  },
  "target": {
    "record_id": "urn:uuid:057632ba-a49e-4634-a9eb-4bfd23bf2152",
    "version": 1,
    "content_hash": "sha256:2deada6b6475efbcc3ecaabde8e76669c419610ce8f1283d35ac3247cf805645"
  },
  "published_grade": {
    "profile": "wrs-published-grade-1",
    "edition": "2026-10-28.1",
    "id": "chen-team-lateral-casimir-force-corrugations-2002",
    "entry_id": "chen-team-lateral-casimir-force-corrugations-2002",
    "revision": 1,
    "title": "Lateral Casimir force between corrugated surfaces",
    "context": "Quantum Physics",
    "track": "Source-reported experimental result or reusable measurement method",
    "band": "A",
    "modifier": "-",
    "status": "PROVISIONAL_EDITORIAL",
    "assessed_on": "2026-10-28",
    "evidence_cutoff": "2026-10-28",
    "achievement_state": "SUPPORTED_SCOPED_RESULT",
    "what_changed": "Chen and colleagues used a modified atomic-force microscope to measure an oscillating lateral force between aligned, corrugated gold-coated surfaces. Its phase dependence followed the corrugation period, and the authors compared its magnitude and distance dependence with a finite-conductivity Casimir calculation for their sphere–plate geometry. Their later detailed account reports the calibration, additional electrostatic-force data and a more comprehensive uncertainty analysis.",
    "scope": "Chen and colleagues used a modified atomic-force microscope to measure an oscillating lateral force between aligned, corrugated gold-coated surfaces. Its phase dependence followed the corrugation period, and the authors compared its magnitude and distance dependence with a finite-conductivity Casimir calculation for their sphere–plate geometry. Their later detailed account reports the calibration, additional electrostatic-force data and a more comprehensive uncertainty analysis. The measurement is a small lateral deflection in a particular corrugated sphere–plate setup, with electrostatic compensation and calibration; it is not a general measurement of all geometries or a working vacuum-powered machine. The absolute closest Casimir separation is inferred from the same force theory used for comparison, followed by calibrated 12 nm increments. A separate lateral-electrostatic measurement constrains contact separation but was made hours later and also uses a force model; it does not make the absolute force-law test fully independent. The initial letter quotes about 15% relative uncertainty at 95% confidence; the detailed account reports about 24% after fuller error analysis. The surface alignment and roughness assumptions apply to this setup. Earlier theory of lateral forces and prior normal Casimir measurements retain credit.",
    "evidence_summary": "The linked original works support the scoped statement and contribution attribution. WRS has not independently replayed experiments or reconstructed a full mathematical proof. The measurement is a small lateral deflection in a particular corrugated sphere–plate setup, with electrostatic compensation and calibration; it is not a general measurement of all geometries or a working vacuum-powered machine. The absolute closest Casimir separation is inferred from the same force theory used for comparison, followed by calibrated 12 nm increments. A separate lateral-electrostatic measurement constrains contact separation but was made hours later and also uses a force model; it does not make the absolute force-law test fully independent. The initial letter quotes about 15% relative uncertainty at 95% confidence; the detailed account reports about 24% after fuller error analysis. The surface alignment and roughness assumptions apply to this setup. Earlier theory of lateral forces and prior normal Casimir measurements retain credit.",
    "references": [
      {
        "title": "Demonstration of the Lateral Casimir Force",
        "url": "https://web.mit.edu/kardar/Desktop/kardar/www/research/seminars/Casimir/PRL-ChenMohideen02.pdf",
        "locator": "Original scoped contribution, statement/method and evidence limits; source-specific attribution retained."
      },
      {
        "title": "Experimental and Theoretical Investigation of the Lateral Casimir Force Between Corrugated Surfaces",
        "url": "https://arxiv.org/pdf/quant-ph/0209167v1",
        "locator": "Original scoped contribution, statement/method and evidence limits; source-specific attribution retained."
      }
    ],
    "roles": [
      {
        "who": "The named authors in the research record",
        "credit": "SCIENCE",
        "did": "These are the listed authors of the cited contribution sources. Paper authorship does not quantify individual effort. An incomplete list is explicitly marked; same names are not automatically merged."
      }
    ],
    "target": {
      "record_id": "urn:uuid:057632ba-a49e-4634-a9eb-4bfd23bf2152",
      "version": 1,
      "content_hash": "sha256:2deada6b6475efbcc3ecaabde8e76669c419610ce8f1283d35ac3247cf805645"
    },
    "scientific_correctness_certified": false,
    "independent_expert_calibration": false,
    "method": "PROPRIETARY",
    "points": "85000"
  },
  "canonical_agent_submission": false,
  "scientific_verification_awarded": false,
  "reader_guide": null,
  "reading_status": "SOURCE_LINKED_NOTE"
}